Knowledge base
The facts buyers and researchers ask for most — latex vs nitrile, medical vs industrial, and the standards that matter.
Latex vs nitrile
| Natural latex | Nitrile | |
|---|---|---|
| Material | Natural rubber latex | 100% synthetic (NBR) |
| Standards | ASTM D3578, EN 455, ISO 11193-1 (Type 1) | ASTM D6319, EN 455, ISO 11193-1 (Type 2) |
| Powder | Powdered or powder-free | Powder-free |
| Fit & comfort | Excellent fit and comfort | Good; textured fingertips |
| Puncture resistance | Standard | About 3× latex (manufacturer claim) |
| Allergy | Can trigger latex allergy | Latex-free |
| Chemical resistance | Moderate | Stronger |
| Shelf life | 3 years | 3 years |
| Typical use | Examination, general | Medical examination (US default) |
Product data per manufacturer specification sheets (ASTM / EN / ISO). The “3× puncture resistance” figure is a manufacturer claim, not an independent test result.
Medical examination vs industrial / general-purpose gloves
These two lines must never be mixed. Industrial / general-purpose gloves have NO FDA medical clearance. Quoting, labelling or declaring them as medical gloves is a compliance breach.
| Medical examination gloves | Industrial / general-purpose gloves | |
|---|---|---|
| Regulation (US) | FDA medical device (21 CFR 880.6250) | Not an FDA medical device — FDA has no jurisdiction |
| US market entry | Establishment registration, product listing, 510(k) where applicable | No FDA clearance needed or available |
| EU | MDR 2017/745, Class I | PPE Regulation 2016/425, Category III |
| Standards | EN 455, ASTM D3578 / D6319, AQL 1.5–2.5 | EN ISO 374-1 (Type B), EN ISO 374-4 |
| Typical buyer | Hospitals, clinics, distributors | Factories, workshops, food handling |
Standards that matter
- ISO 13485:2016 — quality management for medical devices. Expected by most serious medical buyers, though not legally mandatory for EU Class I.
- ISO 9001 — general quality management.
- CE, EU PPE Regulation 2016/425, Category III — for PPE gloves; type examination by a notified body (e.g. SATRA, notified body 2777).
- EN 455 — medical gloves (freedom from holes, physical properties, biological evaluation).
- EN ISO 374 — chemical and micro-organism protective gloves.
- ASTM D3578 (latex) and ASTM D6319 (nitrile) — US specification standards for examination gloves.
Frequently asked questions
Are Malaysian gloves the world's largest source of supply?
Malaysia accounted for about 45% of global glove sales in 2024 (MARGMA / CIMB) and 56.4% of US nitrile and latex glove imports in January–July 2026 (USITC DataWeb). Its US share has been slipping — 62% in December 2025 to 50% in July 2026 (RHB Research) — with Vietnam and Indonesia taking most of the lost share.
What is the difference between medical examination gloves and industrial gloves?
Medical examination gloves are regulated as medical devices. To sell them in the United States they need FDA establishment registration, product listing and, where applicable, a 510(k). Industrial / general-purpose gloves are NOT medical devices: the FDA has no jurisdiction over gloves sold for general purposes such as construction or industrial work, and they carry no FDA medical clearance. The two lines must be quoted, labelled and customs-declared separately.
Why did nitrile glove prices fall in 2026?
Generic nitrile ASP fell from a May 2026 peak of US$27–28 per 1,000 pieces to US$19–20 in September 2026 (RHB Research), because global capacity (about 451 billion pieces a year) exceeds demand (about 344 billion in 2026), leaving an oversupply of roughly 107 billion pieces. Malaysian makers raised prices by US$2–2.5 per carton in October 2026, but mainly to pass through higher gas and feedstock costs, not because pricing power returned.
What is the US tariff on Chinese vs Malaysian medical gloves?
Chinese medical gloves face 112.5% into the US (100% Section 301 from 1 January 2026 plus 12.5% forced-labour Section 301). Malaysian medical gloves face 10% under the Section 301 measure in force from 24 July 2026 (MITI parliamentary reply, 28 October 2026).
What is the Section 232 medical-PPE investigation?
The US Department of Commerce launched a Section 232 national-security investigation covering medical PPE, including gloves, in September 2025. No decision had been published as of 23 November 2026 — the decision expected in November 2026 had not materialised, and the BIS investigations page still listed the case as open on 22 November 2026. This page will be updated when a decision lands.
Latex or nitrile — which is better?
Neither is universally better. Natural latex gloves (ASTM D3578, EN 455, ISO 11193-1 Type 1) offer comfort and fit but can trigger latex allergy. Nitrile gloves (ASTM D6319, EN 455, ISO 11193-1 Type 2) are latex-free, with stronger chemical and puncture resistance, and are the default for medical examination use in the US. The choice depends on the application, allergy policy and chemical exposure.
Answers are compiled from the sources named in each answer. See the weekly report archive for the underlying data.